Part Number Hot Search : 
H1200 DL4758A TLP3914 CMR200T 74LV02N MAX8575 AAT2803 324001P
Product Description
Full Text Search
 

To Download CCT-49K640-M Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ? 2016 teledyne relays (800) 284-7007 ? www.teledynecoax.com cct-49k/ct-49k page 1 cct-49k\ct-49k\072016q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches electrical characteristics form factor multi-throw, break before make frequency range cct-49k ct-49k dc?40 ghz dc?40 ghz characteristic impedance 50 ohms operate time 20 ms (max.) terminations 50 actuation voltage available 12 15 24 28 v actuation current 255 205 130 90 ma reset current (# of positions) 3 765 615 390 270 ma 4 1020 820 520 360 ma 5 1275 1025 650 450 ma 6 1530 1230 780 540 ma environmental and physical characteristics operating temperature commercial model, cct-49k elite model, ct-49k ?40c to 65c ?55c to 85c vibration (mil-std-202 method 214, condition d, non-operating) 10 g?s rms shock (mil-std-202 method 213, condition d, non-operating) 500 g?s standard actuator life actuator life w/ additional features 5,000,000 cycles 1,000,000 cycles connector type 2.92mm (k) humidity (moisture seal) available weight 6 oz. (170.1g) (max.) part number description cct-49k commercial latching multi-throw, dc-40 ghz ct-49k elite latching multi-throw, dc-40ghz the cct-49k/ct-49k is an internally terminated broadband, multi-throw, electromechanical coaxial switch designed to switch a microwave signal from a common input to any of 3, 4, 5, or 6 outputs. the characteristic impedance is 50 ohms. internal terminations provide an impedence match for the unselected ports. the switches are small using the popular connector spacing on a 1.062? dia. circle. each position has an individual actuator mechanism allowing random position selection. this also minimizes switching time. the cct-49k/ct-49k comes with a latching actuator. the latching switch remains in the last position selected when the switch is de-energized. std dual command requires a reset pulse before a new selected position. a separate reset circuit allows all positions to be set to an open position. user must provide both reset (clear) and set (select new position) commands. part numbering system for additional options, please contact factory. actuator voltage cct-49 k 6 6 c - t ** series connectors actuator type options number of positions * d-sub connector may be 9 or 15 pin depending on number of throws. (see connector pinout page) connector actuator voltage number of positions actuator type options k : 2.92mm female 6: 28 vdc latching 3: sp 3 t 0 : no indicator contacts t : ttl drivers with diodes 7: 15 vdc latching 4: sp 4 tc : indicator contacts d : coil transient suppression diodes 8: 12 vdc latching 5: sp 5 t d : self cutoff only r : positive + common 9: 24 vdc latching 6: sp 6 ttd : decoders and ttl drivers with diodes ** see parts list on page 11-13 m : moisture seal s : d - sub connector * for maximum limits, please see charts on pages 6-8 available with usb & ethernet control! click here mmc series performance characteristics frequency dc?12 ghz 12?18 ghz 1 8?28 ghz 28?36 ghz 36?40 ghz insertion loss, db, max. 0.2 0.4 0.5 1.0 1.4 isolation, db, min. 75 70 70 60 60 vswr , max. 1.25:1 1.50:1 1.5:1 1.80:1 2.10:1
cct-49k/ct-49k page 2 specifications are subject to change without notice ? 2016 teledyne coax switches cct-49k\ct-49k\072016\q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches schematics and mechanical outline ?- s option ? 9 - pin , 15- pin , 26- pin d - sub connector ( example : cct -49k s 660- s ) sp3t sp4t sp5t sp6t analog indicators ttl h = 2.25 std & indicator models h = 2.50 all other models 14x solder terminals solder wire maximum temp 250oc for no more than 5 sec indicators (positive common)
? 2016 teledyne relays (800) 284-7007 ? www.teledynecoax.com cct-49k/ct-49k page 3 cct-49k\ct-49k\072016q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches 9-pin d-sub connector 1 9 15-pin d-sub connector connector pinout for latching sp3t multi-throw switches e xample ct-49k630-s ct49k63c-s ct49k630-ts ct49k63c-ts ct49k630-tds ct49k63c-tds i ndicator y es y es y es ttl y es y es d ecoders & ttl y es y es pin no. 9-p in 15-p in 9-p in 15-p in 9-p in 15-p in 1p ort 1p ort 1 ttl 1 ttl 1 l ogic 1l ogic 1 2p ort 2p ort 2 ttl 2 ttl 2 l ogic 2l ogic 2 3p ort 3p ort 3 ttl 3 ttl 3 l ogic 3l ogic 3 4 5 6 7c ommon c ommon c ommon c ommon c ommon c ommon 8r eset r eset r eset r eset 9 vsw vsw vsw vsw 10 d i ndicator (com) d i ndicator (com) d i ndicator (com) 11 e i ndicator e i ndicator e i ndicator 12 f i ndicator f i ndicator f i ndicator 13 g i ndicator g i ndicator g i ndicator 14 15 connector pinout for latching sp4t multi-throw switches e xample ct-49k640-s ct49k64c-s ct49k640-ts ct49k64c-ts ct49k640-tds ct49k64c-tds i ndicator y es y es y es ttl y es y es d ecoders & ttl y es y es pin no. 9-p in 15-p in 9-p in 15-p in 9-p in 15-p in 1p ort 1p ort 1 ttl 1 ttl 1 l ogic 1l ogic 1 2p ort 2p ort 2 ttl 2 ttl 2 l ogic 2l ogic 2 3p ort 3p ort 3 ttl 3 ttl 3 l ogic 3l ogic 3 4p ort 4p ort 4 ttl 4 ttl 4 5 6 7c ommon c ommon c ommon c ommon c ommon c ommon 8r eset r eset r eset r eset 9 vsw vsw vsw vsw 10 d i ndicator (com) d i ndicator (com) d i ndicator (com) 11 e i ndicator e i ndicator e i ndicator 12 f i ndicator f i ndicator f i ndicator 13 g i ndicator g i ndicator g i ndicator 14 h i ndicator h i ndicator h i ndicator 15 connector pinout for latching sp5t multi-throw switches e xample ct-49k650-s ct49k65c-s ct49k650-ts ct49k65c-ts ct49k650-tds ct49k65c-tds i ndicator y es y es y es ttl y es y es d ecoders & ttl y es y es pin no. 9-p in 15-p in 9-p in 15-p in 9-p in 15-p in 1p ort 1p ort 1 ttl 1 ttl 1 l ogic 1l ogic 1 2p ort 2p ort 2 ttl 2 ttl 2 l ogic 2l ogic 2 3p ort 3p ort 3 ttl 3 ttl 3 l ogic 3l ogic 3 4p ort 4p ort 4 ttl 4 ttl 4 5p ort 5p ort 5 ttl 5 ttl 5 6 7c ommon c ommon c ommon c ommon c ommon c ommon 8r eset r eset r eset r eset 9 vsw vsw vsw vsw 10 d i ndicator (com) d i ndicator (com) d i ndicator (com) 11 e i ndicator e i ndicator e i ndicator 12 f i ndicator f i ndicator f i ndicator 13 g i ndicator g i ndicator g i ndicator 14 h i ndicator h i ndicator h i ndicator 15 k i ndicator k i ndicator k i ndicator
cct-49k/ct-49k page 4 specifications are subject to change without notice ? 2016 teledyne coax switches cct-49k\ct-49k\072016\q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches connector pinout for latching sp6t multi-throw switches e xample ct-49k660-s ct49k66c-s ct49k660-ts ct49k66c-ts ct49k660-tds ct49k66c-tds i ndicator y es y es y es ttl y es y es d ecoders & ttl y es y es pin no. 9-p in 15-p in 9-p in 15-p in 9-p in 15-p in 1p ort 1p ort 1 ttl 1 ttl 1 l ogic 1l ogic 1 2p ort 2p ort 2 ttl 2 ttl 2 l ogic 2l ogic 2 3p ort 3p ort 3 ttl 3 ttl 3 l ogic 3l ogic 3 4p ort 4p ort 4 ttl 4 ttl 4 5p ort 5p ort 5 ttl 5 ttl 5 vsw 6p ort 6p ort 6 ttl 6 ttl 6 7c ommon c ommon c ommon c ommon c ommon c ommon 8r eset r eset r eset r eset 9d i ndicator (com) vsw vsw vsw d i ndicator (com) 10 e i ndicator e i ndicator 11 f i ndicator f i ndicator 12 g i ndicator g i ndicator 13 h i ndicator h i ndicator 14 k i ndicator k i ndicator 15 l i ndicator d i ndicator (com) l i ndicator 16 e i ndicator 17 f i ndicator 18 g i ndicator 19 h i ndicator 20 k i ndicator 21 l i ndicator 22 23 24 25 26 26-pin d-sub connector 1 9 15-pin d-sub connector
? 2016 teledyne relays (800) 284-7007 ? www.teledynecoax.com cct-49k/ct-49k page 5 cct-49k\ct-49k\072016q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches truth table latching cct-49kx4c-td logic input rf path indicator switches 123 j1j2j3j4reset efgh 000 on off off off off c 000 100 off on off off off 0 c 00 010 offoff on off off 0 0 c 0 1 1 0 off off off on off 0 0 0 c 0 1 1 off off off off reset 0 0 0 0 1 1 1 coil off 0 0 0 0 truth table latching cct-49kx3c-td logic input rf path indicator switches 123 j1j2j3reset efg 000 on off off off c 00 100 off on off off 0 c 0 010 offoff on off 0 0 c 0 1 1 off off off reset 0 0 0 111 coil off 000 truth table latching cct-49kx3c-t logic input rf path indicator switches 123r j1j2j3reset efg 1000 on off off off c 00 0100 off on off off 0 c 0 0010 offoff on off 0 0 c truth table latching cct-49kx4c-t logic input rf path indicator switches 1234r j1j2j3j4reset efgh 10000 on off off off off c 000 01000 off on off off off 0 c 00 00100 offoff on off off 0 0 c 0 00010 offoffoff on off 0 0 0 c
cct-49k/ct-49k page 6 specifications are subject to change without notice ? 2016 teledyne coax switches cct-49k\ct-49k\072016\q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches truth table latching cct-49kx6c-td logic input rf path indicator switches 1 2 3 j1 j2 j3 j4 j5 j6 reset e f g h k l 000 on off off off off off off c 00000 100 off on off off off off off 0 c 0000 010 offoff on off off off off 0 0 c 000 1 1 0 off off off on off off off 0 0 0 c 00 0 0 1 off off off off on off off 0000 c 0 1 0 1 off off off off off on off 00000 c 0 1 1 offoffoffoffoffoffreset 000000 1 1 1 coil off 000000 truth table latching cct-49kx5c-td logic input rf path indicator switches 1 2 3 j1 j2 j3 j4 j5 reset e f g h k 000 on off off off off off c 0000 100 off on off off off off 0 c 000 010 offoff on off off off 0 0 c 00 1 1 0 off off off on off off 000 c 0 0 0 1 off off off off on off 0000 c 0 1 1 off off off off off reset 0 0 0 0 0 1 1 1 coil off 00000 truth table latching cct-49kx5c-t logic input rf path indicator switches 12345r j1j2j3j4j5reset efghk 100000 on off off off off off c 0000 010000 off on off off off off 0 c 000 001000 offoff on off off off 0 0 c 00 000100 offoffoff on off off 0 0 0 c 0 000010 offoffoffoff on off 0 0 0 0 c truth table latching cct-49kx6c-t logic input rf path indicator switches 123456r j1j2j3j4j5j6reset efghkl 1000000 on off off off off off off c 00000 0100000 off on off off off off off 0 c 0000 0010000 offoff on off off off off 0 0 c 000 0001000 offoffoff on off off off 0 0 0 c 00 0000100 offoffoffoff on off off 0000 c 0 0000010 offoffoffoffoff on off 00000 c
? 2016 teledyne relays (800) 284-7007 ? www.teledynecoax.com cct-49k/ct-49k page 7 cct-49k\ct-49k\072016q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches typical rf performance curves 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 0 5 10 15 20 25 30 35 40 -1.2 -1 -0.8 -0.6 -0.4 -0.2 0 0 5 10 15 20 25 30 35 40 insertion loss frequency (ghz) frequency (ghz) insertion loss (db) vswr (db) vswr
cct-49k/ct-49k page 8 specifications are subject to change without notice ? 2016 teledyne coax switches cct-49k\ct-49k\072016\q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches typical rf performance curves -120 -100 -80 -60 -40 -20 0 0 5 10 15 20 25 30 35 40 frequency (ghz) isolation (db) isolation
? 2016 teledyne relays (800) 284-7007 ? www.teledynecoax.com cct-49k/ct-49k page 9 cct-49k\ct-49k\072016q3 series cct-49k/ct-49k internal 50 termination dc-40 ghz latching multi-throw coaxial switch coax switches power handling vs. frequency estimates based on the following reference conditions: ? ambient temperature of 40c or less ? sea level operation ? load vswr of 1.20:1 maximum ? no high-power (hot) switching please contact teledyne coax switches for derating factors when applications do not meet the foregoing reference conditions. typical power performance curve 3000 power (w) frequency ghz 2000 1000 800 600 400 300 200 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 4 6 8 10 18 26.5 5 40 special high power switches standard sma switches standard n & tnc switches standard k switches


▲Up To Search▲   

 
Price & Availability of CCT-49K640-M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X